CONDENSERS

WHP - 10 SEER Heat Pump Condensers

WHP 10 SEER Heat Pump Condensers ***SUBJECT TO AVAILABILITY***

New government regulations have all but depleted availability of 10 SEER  systems. However, Hamilton still has these units available while our supplies last.

10 SEER condensers cost up to 40% less to purchase than 13 SEER systems, which have been mandated as the "NEW MINIMUM EFFICIENCY" by the U.S. government!

WLE - 10 SEER Heat Pump Condensers

The WHP series single phase Heat Pump from Hamilton gives year-round comfort. It works just like an air conditioner in the summer, and provides heat in the winter. All of our Heat Pumps are pre-charged at the factory and are equipped with quick connect fittings. Installation time and expense are reduced since there is no brazing or charging on most typical installations.

 

These systems may be used with an air handler or furnace. When using with a natural gas, LP gas, or oil furnace, an outdoor thermostat and fossil fuel kit must be used. (See Heat Pump Accessories for details.)

1 Year Limited Parts Warranty5 Year Limited Compressor Warranty

Basic Condenser Layout

FEATURES


  • Condensers are pre-charged with R-22 refrigerant and have quick connect fittings to reduce installation time when matched with our indoor coils and line sets.

  • Reversing valve automatically changes from cooling to heating while accumulator regulates different refrigeration needs of both heating and cooling cycles.

  • Internally protected compressor to guard against high pressure and temperature.

  • Weatherized pre-painted steel casing to resist corrosion & rust.

  • Factory installed solid core filter-drier and high pressure relief valve protect the system and extend compressor life.

  • Top air discharge keeps air away from structure and landscaping.

  • Color coded wiring makes unit easy to service.

  • Long-life, maintenance-free fan motor with sealed, permanently lubricated motor bearings.

  • Approved for Mobile Home Use

HOW TO SELECT A 10 SEER HEAT PUMP SYSTEM

Estimate the Heat Pump System Size

You can refer to an estimate or proposal from a local contractor, refer to the size of your existing system that you may want replaced, or use the sizing estimation chart provided on this page.

 

Use the map to determine your Region based on the location of your home. Using the equipment charts, find your Region and go down the column to locate the range that covers the Square Footage of your home. Follow the row to the right to determine the recommended System Size for your Air Handler.

Estimate the Heating and Cooling Size for your home.

NOTE: These tables and charts are intended to be used as a guideline only. The information is based on conventional window space (<15%), insulation and building construction. Only use these tables as a reference. When including a finished basement, use 1/2 of the finished basement square footage with the rest of the area being calculated.

10 SEER HEAT PUMP CONDENSER SELECTION

 SQUARE FOOTAGE OF YOUR HOME

SYSTEM

 SIZE

REGION 1 REGION 2 REGION 3 REGION 4 REGION 5
1400 - 1675 1300 -1575 1300 - 1500 1000 - 1225 1000 - 1225 2 TON
1675 - 2050 1575 - 1925 1500 - 1825 1225 - 1500 1225 - 1500 2.5 TON
2050 - 2425 1925 - 2300 1825 - 2150 1500 - 1775 1500 - 1775 3 TON
2425 - 2800 2300 - 2650 2150 - 2500 1775 - 2050 1775 - 2050 3.5 TON


3.5 Ton 10 SEER Heat Pump System

Only Size Available

10 SEER Condensers

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WHP 42C

27 x 37 x 27

3.5

180

10 SEER Indoor Coils (Chose One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WMQ 48-21C

24 x 21 x 22

Fits furnaces with 21" unit width.

3.5-4.0

65

WMQ 48-24C*

24 x 24.5 x 22

Fits furnaces with 24.5" unit width.

3.5-4.0

74

Item #

Description

For use with

Wt. (lbs.)

WLS-20C

20' - 3/4" dia. Refrigerant Line Set

2.0-3.5 Ton Systems

20

WLS-30C

30' - 3/4" dia. Refrigerant Line Set

4.0-5.0 Ton Systems

25

WLS-40C

40' - 3/4" dia. Refrigerant Line Set

4.0-5.0 Ton Systems

40

Item #

Description

Wt. (lbs.)

1F72-151

5 Day / 2 Day Digital Programmable "Heat Pump" Thermostat

For all heat pump applications including fossil fuel furnaces.

1

ACPD 3040

"Easy-To Install" Condenser Pad (28" X 38")

Reduces condenser noise and vibration.

26

WKDP-21

Custom Supply Air Plenum to fit 21" coil case width.

28

* THERE ARE CURRENTLY NO CUSTOM PLENUMS AVAILABLE FOR 24.5" COIL WIDTH

 

Available PDF downloads for:

WHP - 10 SEER Heat Pump Condensers

Get Adobe Reader

Hamilton Home Products, Inc. - 1-800-879-0123 - www.HamiltonHomeProducts.com


© Copyright 2010 Hamilton Home Products, Inc.

Copyright in all of the material on the Hamilton Home Products, Inc. and associated websites, including but not limited to information, text, artwork, images, and pictures (herein referred to as "CONTENT"), is either owned by or administered by Hamilton Home Products, Inc. (for the purpose of this notice Hamilton Home Products shall include Hamilton, its employees, servants and agents) for and on behalf of Hamilton Home Products, Inc. P.O. Box 185, Canal Winchester, Ohio 43110