13 SEER Quick Connect R-410A Air Conditioning Systems

Must Order as a Complete System

The new quick connect R-410A systems are perfect for new construction and customers wanting to add A/C to an existing forced air heating system. Each component (Condenser, Coil and Line Set) is pre-charged from the factory with R-410A refrigerant and has quick connect fittings. When properly matched, installation time and expense are reduced since there is no brazing or charging on most typical installations.

10-Year Limited Parts Warranty*

10-Year Limited Compressor Warranty

Please Note:  As of January 1, 2010, The EPA requires all New Construction applications and installations where there was no R-22 system in place to have R-410A equipment installed. *Standard Warranty 5-Years Limited Parts. Must apply online within 60 days of closing or replacement at www.stylecrestproducts.com for the Extended 10-Year Limited Parts Warranty.

4AC Condensers:

- Factory pre-charged with R-410A refrigerant with quick connect fittings

- Internally protected compressor to guard against high pressure and temperature

- Weatherized pre-painted steel casing to resist corrosion & rust

- Factory installed liquid line filter drier

- Top warm air discharge keeps air away from structure and landscaping

- Color coded wiring makes unit easy to service

- Low sound level during unit operation

- Long-life, maintenance-free fan motor with sealed, permanently lubricated motor bearings

- Approved for Mobile Home Use when matched with the appropriate mobile home R-410A coil and line set

4QC Coils

- Factory pre-charged with R-410A refrigerant with quick connect fittings

- Fully cased multi-positional design for residential applications

- Enhanced performance with TXV (Thermal Expansion Valve) to meter the refrigerant

- Includes horizontal drain pan and condensate blow-off shield

- Coil may be removed from the case and placed inside an existing plenum

4LS Line Sets

- Factory pre-charged with R-410A refrigerant with quick connect fittings

- Designed for residential applications

- Includes 3/8" liquid line and either 3/4" or 7/8" insulated suction line

NOTE: When replacing an older R-22 air conditioning or heat pump system, all components (condenser, coil, and line set)  MUST be replaced or the system warranties will be voided.

HOW TO SELECT A 13 SEER AIR CONDITIONING SYSTEM

Estimating the A/C System Size

You can refer to an estimate or proposal from a local contractor, refer to the size of your existing system that you may want replaced, or use the sizing estimation chart provided on this page.

 

Use the map to determine your Region based on the location of your home. Using the equipment charts, find your Region and go down the column to locate the range that covers the Square Footage of your home. Follow the row to the right to determine the recommended System Size for your A/C system.

Estimate the Heating and Cooling Size for your home.

NOTE: These tables and charts are intended to be used as a guideline only. The information is based on conventional window space (<15%), insulation and building construction. Only use these tables as a reference. When including a finished basement, use 1/2 of the finished basement square footage with the rest of the area being calculated.

13 SEER AIR CONDITIONING CONDENSER SELECTION

 SQUARE FOOTAGE OF YOUR HOME

SYSTEM

 SIZE

REGION 1 REGION 2 REGION 3 REGION 4 REGION 5
1310-1680 1235-1580 1165-1500 955-1225 955-1225 2 TON
1680-2060 1580-1940 1500-1830 1225-1500 1225-1500 2.5 TON
2060-2435 1940-2290 1830-2165 1500-1770 1500-1770 3 TON
2435-2810 2290-2645 2165-2500 1770-2045 1770-2045 3.5 TON
2810-3375 2645-3175 2500-3000 2045-2455 2045-2455 4 TON

 

2 Ton Air Conditioning System

Condenser

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4AC24Q

28 x 23.5 x 23.5

2.0

145

Indoor Coil (Select One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4QC30-14Q

24.0625 x 14.5 x 21.5

fits furnaces with 14.5" unit width

2.0-2.5

49

4QC36-17Q

24.0625 x 17.5 x 21.5

fits furnaces with 17.5" unit width

2.0-3.0

51

Line Set (Select One)

Item #

Description

For use with

Wt. (lbs.)

4LS20C

20' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

13

4LS30C

30' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

18

4LS40C

40' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

23

Optional Items

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat

for Single Stage heating and cooling applications

1

ACPD2424

"Easy-To Install" Condenser Pad (24 x 24" x 2")

reduces condenser noise and vibration

15

WKDP-14

Custom Supply Air Plenum

plenum kit to fit 14.5" coil case width

24

WKDP-17

Custom Supply Air Plenum

plenum kit to fit 17.5" coil case width

26

 

2.5 Ton Air Conditioning System  

Condenser

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4AC30Q

28 x 23.5 x 23.5

2.5

165

Indoor Coil (Select One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4QC30-14Q

24.0625 x 14.5 x 21.5

fits furnaces with 14.5" unit width

2.0-2.5

49

4QC36-17Q

24.0625 x 17.5 x 21.5

fits furnaces with 17.5" unit width

2.0-3.0

51

4QC42-17Q

24.0625 x 17.5 x 21.5

fits furnaces with 17.5" unit width

2.5-3.5

65

4QC42-21Q

26.0625 x 21 x 21.5

fits furnaces with 21" unit width

2.5-3.5

68

Line Set (Select One)

Item #

Description

For use with

Wt. (lbs.)

4LS20C

20' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

13

4LS30C

30' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

18

4LS40C

40' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

23

Optional Items

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat For Single Stage heating and cooling applications.

1

ACPD2424

"Easy-To Install" Condenser Pad (24 x 24" x 2")

reduces condenser noise and vibration

15

WKDP-14

Custom Supply Air Plenum

plenum kit to fit 14.5" coil case width

24

WKDP-17

Custom Supply Air Plenum

plenum kit to fit 17.5" coil case width

26

WKDP-21

Custom Supply Air Plenum

Plenum Kit to fit 21" coil case width

28

 

3 Ton Air Conditioning System

 

Condenser

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4AC36Q

28 x 29 x 29

3.0

175

Indoor Coil (Select One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4QC36-17Q

24.0625 x 17.5 x 21.5

fits furnaces with 17.5" unit width

2.0-3.0

51

4QC42-17Q

24.0625 x 17.5 x 21.5

fits furnaces with 17.5" unit width

2.5-3.5

65

4QC42-21Q

26.0625 x 21 x 21.5

fits furnaces with 21" unit width

2.5-3.5

68

Line Set (Select One)

Item #

Description

For use with

Wt. (lbs.)

4LS20C

20' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

13

4LS30C

30' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

18

4LS40C

40' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

23

Optional Items

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat For Single Stage heating and cooling applications.

1

ACPD3030-3

"Easy-To Install" Condenser Pad (30 x 30" x 3")

reduces condenser noise and vibration

15

WKDP-17

Custom Supply Air Plenum

plenum kit to fit 17.5" coil case width

26

WKDP-21

Custom Supply Air Plenum

plenum Kit to fit 21" coil case width

28

 

3.5 Ton Air Conditioning System

Condenser

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4AC42Q

30 x 29 x 29

3.5

190

Indoor Coil (Select One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4QC42-17Q

24.0625 x 17.5 x 21.5

fits furnaces with 17.5" unit width

2.5-3.5

65

4QC42-21Q

26.0625 x 21 x 21.5

fits furnaces with 21" unit width

2.5-3.5

68

4QC60-21Q

26.0625 x 21 x 21.5

fits furnaces with 21" unit width

3.5-4

69

4QC60-24Q

26.0625 x 24.5 x 21.5

fits furnaces with 24.5" unit width

3.5-4

72

Line Set

Item #

Description

For use with

Wt. (lbs.)

4LS30/1A

30' - 7/8" dia. Refrigerant Line Set

3.5-5 Ton Systems

31

Optional Items

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat for single stage heating and cooling applications

1

ACPD3030-3

"Easy-To Install" Condenser Pad (30 x 30" x 3")

reduces condenser noise and vibration

15

WKDP-17

Custom Supply Air Plenum

plenum kit to fit 17.5" coil case width

26

WKDP-21

Custom Supply Air Plenum

plenum Kit to fit 21" coil case width

28

* THERE ARE CURRENTLY NO CUSTOM PLENUMS AVAILABLE FOR 24.5" COIL WIDTH

 

4 Ton Air Conditioning System

 

Condenser

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4AC48Q

30 x 29 x 29

4.0

191

Indoor Coil (Select One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

4QC60-21Q

26.0625 x 21 x 21.5

fits furnaces with 21" unit width

3.5-4

69

4QC60-24Q

26.0625 x 24.5 x 21.5

fits furnaces with 24.5" unit width

3.5-4

72

Line Set

Item #

Description

For use with

Wt. (lbs.)

4LS30/1A

30' - 7/8" dia. Refrigerant Line Set

3.5-5 Ton Systems

31

 

Optional Items

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat

for single stage heating and cooling applications

1

ACPD3030-3

"Easy-To Install" Condenser Pad (30 x 30" x 3")

reduces condenser noise and vibration

15

WKDP-21

Custom Supply Air Plenum

plenum kit to fit 21" coil case width

28

* THERE ARE CURRENTLY NO CUSTOM PLENUMS AVAILABLE FOR 24.5" COIL WIDTH

Hamilton Home Products, Inc. - 1-800-879-0123 - www.HamiltonHomeProducts.com


© Copyright 2010 Hamilton Home Products, Inc.

Copyright in all of the material on the Hamilton Home Products, Inc. and associated websites, including but not limited to information, text, artwork, images, and pictures (herein referred to as "CONTENT"), is either owned by or administered by Hamilton Home Products, Inc. (for the purpose of this notice Hamilton Home Products shall include Hamilton, its employees, servants and agents) for and on behalf of Hamilton Home Products, Inc. P.O. Box 185, Canal Winchester, Ohio 43110