Additional Information

Buying Hamilton Products

Installations

Warranty Claims

Replacement Parts

CONDENSERS

WAQ - 13 SEER Air Conditioning Condensers

The WAQ series air conditioning condensers meet 13 SEER efficiency requirements. These units are pre-charged at the factory and are equipped with quick connect fittings. When matched with one of our coils and line sets, installation time and expense are reduced since there is no brazing or charging on most typical installations.

2 Year Limited Parts Warranty5 Year Limited Compressor Warranty

FEATURES


  • Condensers are pre-charged with R-22 refrigerant and have quick connect fittings to reduce installation time when matched with our indoor coils and line sets.

  • Internally protected compressor to guard against high pressure and temperature.

  • Weatherized pre-painted steel casing to resist corrosion & rust.

  • Factory installed liquid line filter drier.

  • Top warm air discharge keeps air away from structure and landscaping.

  • Color coded wiring makes unit easy to service.

  • Low sound level during unit operation.

  • Long-life, maintenance-free fan motor with sealed, permanently lubricated motor bearings.

  • Approved for Mobile Home Use

NOTE: It is recommended to completely replace older air conditioning and heat pump systems in order to achieve proper 13 SEER system efficiency and operation. Matching a 13 SEER condenser with a 13 SEER indoor coil will ensure optimum efficiency and peak operating performance.

HOW TO SELECT A 13 SEER AIR CONDITIONING SYSTEM

Estimating the A/C System Size

You can refer to an estimate or proposal from a local contractor, refer to the size of your existing system that you may want replaced, or use the sizing estimation chart provided on this page.

 

Use the map to determine your Region based on the location of your home. Using the equipment charts, find your Region and go down the column to locate the range that covers the Square Footage of your home. Follow the row to the right to determine the recommended System Size for your A/C system.

Estimate the Heating and Cooling Size for your home.

NOTE: These tables and charts are intended to be used as a guideline only. The information is based on conventional window space (<15%), insulation and building construction. Only use these tables as a reference. When including a finished basement, use 1/2 of the finished basement square footage with the rest of the area being calculated.

13 SEER AIR CONDITIONING CONDENSER SELECTION

 SQUARE FOOTAGE OF YOUR HOME

SYSTEM

 SIZE

REGION 1 REGION 2 REGION 3 REGION 4 REGION 5
1310-1680 1235-1580 1165-1500 955-1225 955-1225 2 TON
1680-2060 1580-1940 1500-1830 1225-1500 1225-1500 2.5 TON
2060-2435 1940-2290 1830-2165 1500-1770 1500-1770 3 TON
2435-2810 2290-2645 2165-2500 1770-2045 1770-2045 3.5 TON
2810-3375 2645-3175 2500-3000 2045-2455 2045-2455 4 TON

2 Ton 13 SEER Air Conditioning Systems

Complete Split System Breakdown

10 SEER Condensers

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WAQ 24

28 x 23.5 x 23.5

2.0

145

10 SEER Indoor Coils (Chose One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WPQ 30-14

24 x 14.5 x 22

Fits furnaces with 14.5" unit width.

2.0-2.5

49

WPQ 30-17

24 x 17.5 x 22

Fits furnaces with 17.5" unit width.

2.0-2.5

51

Item #

Description

For use with

Wt. (lbs.)

WLS-20C

20' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

20

WLS-30C

30' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

25

WLS-40C

40' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

40

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat For Single Stage heating and cooling applications.

1

ACPD 3040

"Easy-To Install" Condenser Pad (28" x 38")

Reduces condenser noise and vibration.

26

WKDP-14

Custom Supply Air Plenum

Plenum kit to fit 14.5" coil case width.

24

WKDP-17

Custom Supply Air Plenum

Plenum kit to fit 17.5" coil case width.

26

 


2.5 Ton 13 SEER Air Conditioning System

Complete Split System Breakdown

10 SEER Condensers

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WAQ 30

32 x 23.5 x 23.5

2.5

165

10 SEER Indoor Coils (Chose One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WPQ 30-14

24 x 14.5 x 22

Fits furnaces with 14.5" unit width.

2.0-2.5

49

WPQ 30-17

24 x 17.5 x 22

Fits furnaces with 17.5" unit width.

2.0-2.5

51

WPQ 36-21

26 x 21 x 22

Fits furnaces with 21" unit width.

2.0-2.5

68

Item #

Description

For use with

Wt. (lbs.)

WLS-20C

20' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

20

WLS-30C

30' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

25

WLS-40C

40' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

40

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat For Single Stage heating and cooling applications.

1

ACPD 3040

"Easy-To Install" Condenser Pad (28" x 38")

Reduces condenser noise and vibration.

26

WKDP-14

Custom Supply Air Plenum

Plenum kit to fit 14.5" coil case width.

24

WKDP-17

Custom Supply Air Plenum

Plenum kit to fit 17.5" coil case width.

26

WKDP-21

Custom Supply Air Plenum

Plenum Kit to fit 21" coil case width.

28

 


3 Ton 13 SEER Air Conditioning System

Complete Split System Breakdown

10 SEER Condensers

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WAQ 36

34 x 23.5 x 23.5

3.0

175

10 SEER Indoor Coils (Chose One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WPQ 36-17

24 x 17.5 x 22

Fits furnaces with 17.5" unit width.

2.5-3.0

65

WPQ 36-21

26 x 21 x 22

Fits furnaces with 21" unit width.

2.5-3.0

68

Item #

Description

For use with

Wt. (lbs.)

WLS-20C

20' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

20

WLS-30C

30' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

25

WLS-40C

40' - 3/4" dia. Refrigerant Line Set

2.0-3.0 Ton Systems

40

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat For Single Stage heating and cooling applications.

1

ACPD 3040

"Easy-To Install" Condenser Pad (28" x 38")

Reduces condenser noise and vibration.

26

WKDP-17

Custom Supply Air Plenum

Plenum kit to fit 17.5" coil case width.

26

WKDP-21

Custom Supply Air Plenum

Plenum Kit to fit 21" coil case width.

28

 


3.5 Ton 13 SEER Air Conditioning System

Complete Split System Breakdown

10 SEER Condensers

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WAQ 42

34 x 29 x 29

3.5

190

10 SEER Indoor Coils (Chose One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WPQ 48-21

26 x 21 x 22

Fits furnaces with 21" unit width.

3.5-4

69

WPQ 48-24

26 x 24.5 x 22

Fits furnaces with 24.5" unit width.

3.5-4

72

Quick Connect Refrigerant Line Set

Item #

Description

For use with

Wt. (lbs.)

WLS-30/1A

30' - 7/8" dia. Refrigerant Line Set

3.5-5 Ton Systems

31

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat For Single Stage heating and cooling applications.

1

ACPD 3040

"Easy-To Install" Condenser Pad (28" x 38")

Reduces condenser noise and vibration.

26

WKDP-21

Custom Supply Air Plenum

Plenum Kit to fit 21" coil case width.

28

* THERE ARE CURRENTLY NO CUSTOM PLENUMS AVAILABLE FOR 24.5" COIL WIDTH

 


4 Ton 13 SEER Air Conditioning System

Complete Split System Breakdown

10 SEER Condensers

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WAQ 48

34 x 29 x 29

4.0

191

10 SEER Indoor Coils (Chose One)

Item #

Dimensions (Inches)

(h x w x d)

Cooling Tons

Wt. (lbs.)

WPQ 48-21

26 x 21 x 22

Fits furnaces with 21" unit width.

3.5-4

69

WPQ 48-24

26 x 24.5 x 22

Fits furnaces with 24.5" unit width.

3.5-4

72

Quick Connect Refrigerant Line Set

Item #

Description

For use with

Wt. (lbs.)

WLS-30/1A

30' - 7/8" dia. Refrigerant Line Set

3.5-5 Ton Systems

31

Item #

Description

Wt. (lbs.)

1F78-151

5 Day / 2 Day Digital Programmable "Heat & Cool" Thermostat For Single Stage heating and cooling applications.

1

WKDP-21

Custom Supply Air Plenum

Plenum Kit to fit 21" coil case width.

28

* THERE ARE CURRENTLY NO CUSTOM PLENUMS AVAILABLE FOR 24.5" COIL WIDTH

 

Available PDF downloads for:

WAC - 13 SEER Air Conditioning Condensers

Get Adobe Reader

WAQ Condenser Installation Manual (146 KB)
WAQ User's Guide (77 KB)
WAQ Technical Guide (134 KB)

WAQ Replacement Parts List

(689 KB)


Hamilton Home Products, Inc. - 1-800-879-0123 - www.HamiltonHomeProducts.com

© Copyright 2008 Hamilton Home Products, Inc.

Copyright in all of the material on the Hamilton Home Products, Inc. and associated websites, including but not limited to information, text, artwork, images, and pictures (herein referred to as "CONTENT"), is either owned by or administered by Hamilton Home Products, Inc. (for the purpose of this notice Hamilton Home Products shall include Hamilton, its employees, servants and agents) for and on behalf of Hamilton Home Products, Inc. P.O. Box 185, Canal Winchester, Ohio 43110