WMA Series
for "Cooling Only" or "Electric Heat with Cooling". |
|
 |
The
quiet and efficient WMA modular air handlers are factory assembled. wired
and tested to assure safe, dependable and economical operation for
residential and commercial applications. The unit’s multi-positional design
accommodates upflow, downflow, and horizontal installation applications
making it ideal for basement, attic, slab, alcove or crawl space locations.
Matching the WMA with our air conditioning systems is a great choice for
customers with boiler and baseboard heat looking to add a cooling only
system. For a complete and efficient electric heating and cooling system,
add the optional WHK heat strip to the WMA and match our
heat pump system. |
|
FEATURES |
|
 |
-
Multi-positional compact cabinet for limited space applications.
-
Standard 240V wiring and breakers.
-
Direct-drive, multiple-speed blower motor is permanently lubricated for
maintenance-free operation with one minute blower-off delay for increased
efficiency.
-
Designed for use with both air conditioning and heat pumps, match the
width of the WMA air handler with the appropriate air conditioning or
heat pump indoor coil.
-
5
Year - Limited Parts Warranty
Not Certified for Mobile Home Use.
SEE SYSTEM ELECTRICAL
REQUIREMENTS
|
|
HOW TO
SELECT AN AIR HANDLER / ELECTRIC FURNACE |
|
Estimating the Furnace Size
You can refer to an estimate or
proposal from a local contractor, refer to the size of your existing
system that you may want replaced, or use the sizing estimation
chart provided on this page.
Use the map to determine your Region based on the location of your home. Using the equipment
charts, find your Region and go down the column to locate the
range that covers the Square Footage of your home. Follow the
row to the right to determine the recommended System Size for your
Air Handler. |
 |
|
NOTE: These tables and charts are
intended to be used as a guideline only. The information is based on
conventional window space (<15%), insulation and building
construction. Only use these tables as a reference. When including a
finished basement, use 1/2 of the finished basement square footage
with the rest of the area being calculated. |
|
|
SQUARE FOOTAGE OF YOUR HOME |
AIR HANDLER
SIZE |
|
REGION
1 |
REGION 2 |
REGION 3 |
REGION 4 |
REGION
5 |
|
935-1680 |
880-1580 |
830-1500 |
680-1225 |
680-1225 |
1.5 -2 TON |
|
1680-2435 |
1580-2290 |
1500-2165 |
1225-1770 |
1225-1770 |
2.5-3
TON |
|
2435-3375 |
2290-3175 |
2165-3000 |
1770-2455 |
1770-2455 |
3.5-4
TON |
|
3375-3935 |
3175-3705 |
3000-3500 |
2455-2860 |
2455-2860 |
5
TON |
|
|
(OPTIONAL) HEAT STRIP SELECTION-
HEATING APPLICATIONS |
|
Heating Applications |
Using the chart below, find your
Region and go down the column to locate the range that covers
the Square Footage of your home. Follow the row to the right to
determine the Heat Strip for your application. |
|
NOTE: The
appropriate Heat Strips that fit each Air Handler are listed in
the equipment charts below. |
|
SQUARE FOOTAGE OF YOUR HOME |
(Optional)
HEAT STRIP SIZE |
|
REGION
1 |
REGION 2 |
REGION 3 |
REGION 4 |
REGION
5 |
|
600-830 |
650-900 |
700-1000 |
850-1220 |
950-1365 |
10 KILOWATT |
|
830-1250 |
900-1350 |
1000-1500 |
1220-1825 |
1365-2050 |
15 KILOWATT |
|
1465-1650 |
1580-1800 |
1770-2000 |
2145-2450 |
2400-2725 |
20 KILOWATT |
|
1650-2080 |
1800-2245 |
2000-2510 |
2450-3050 |
2725-3415 |
25 KILOWATT |
|
* 19 KILOWATT
Electric Heat Strips are for Model WMA 36 Only. |
|
Find the Air Handler Application
Size listed below. Refer to the section on How To Order A Heat
Pump System to verify a complete matched system has been
selected. Note: When selecting the indoor coil, make sure the
width of the coil matches the width of the air handler.
|
|
|
 |
 |
|
Item # |
Dimensions
(Inches)
(h x w x d)
|
Cooling Tons |
Wt. (lbs.) |
|
WMA 24 |
25 x 17.5 x 22 |
1.5-2.0 |
75 |
|
 |
|
WHK Electric Heat Strip
- For
Electric Furnace Applications |
|
Item # |
Max. BTU Output |
Kilowatts |
Wt. (lbs.) |
|
WHK 10 |
34,130 |
10 kW |
6 |
|
 |
|
Item # |
Description |
Wt. (lbs.) |
|
1F78-151 |
5 Day / 2 Day Digital
Programmable "Heat & Cool" Thermostat
For Single Stage heating and cooling
applications. |
1 |
|
|
 |
 |
|
Item # |
Dimensions
(Inches)
(h x w x d)
|
Cooling Tons |
Wt. (lbs.) |
|
WMA 36 |
25 x 17.5 x 22 |
1.5-3.0 |
80 |
 |
|
WHK Electric Heat Strip
- For
Electric Furnace Applications |
|
Item # |
Max. BTU Output |
Kilowatts |
Wt. (lbs.) |
|
WHK 10 |
34,130 |
10 kW |
6 |
|
WHK 15 |
51,195 |
15 kW |
8 |
|
* 19 KILOWATT
Electric Heat Strips are for Model WMA 36 Only. |
|
 |
|
Item # |
Description |
Wt. (lbs.) |
|
1F78-151 |
5 Day / 2 Day Digital
Programmable "Heat & Cool" Thermostat
For Single Stage heating and cooling
applications. |
1 |
|
|
 |
 |
|
Item # |
Dimensions
(Inches)
(h x w x d)
|
Cooling Tons |
Wt. (lbs.) |
|
WMA 48 |
25 x
21 x 22 |
2.5-4.0 |
90 |
 |
|
WHK Electric Heat Strip
- For
Electric Furnace Applications |
|
Item # |
Max. BTU Output |
Kilowatts |
Wt. (lbs.) |
|
WHK 15W |
51,195 |
15 kW |
8 |
|
WHK 20 |
68,260 |
20 kW |
9 |
|
 |
|
Item # |
Description |
Wt. (lbs.) |
|
1F78-151 |
5 Day / 2 Day Digital
Programmable "Heat & Cool" Thermostat
For Single Stage heating and cooling
applications. |
1 |
|
|
 |
|
 |
|
Item # |
Dimensions
(Inches)
(h x w x d)
|
Cooling Tons |
Wt. (lbs.) |
|
WMA 60 |
25 x 24.5 x 22 |
3.5-4.0 |
97 |
 |
|
WHK Electric Heat Strip
- For
Electric Furnace Applications |
|
Item # |
Max. BTU Output |
Kilowatts |
Wt. (lbs.) |
|
WHK 15W |
51,195 |
15 kW |
8 |
|
WHK 20 |
68,260 |
20 kW |
9 |
|
WHK 25 |
85,325 |
25 kW |
9 |
|
 |
|
Item # |
Description |
Wt. (lbs.) |
|
1F78-151 |
5 Day / 2 Day Digital
Programmable "Heat & Cool" Thermostat
For Single Stage heating and cooling
applications. |
1 |
|
|
SYSTEM
ELECTRICAL REQUIREMENTS (230/240V - Single Phase - 60
Hertz) |
|
Hamilton Stock No. |
Cooling Only Applications |
Heating Applications
(With WHK Heat Strips) |
| Breaker Size |
Wire Gauge |
With WHK |
Breaker Size |
Wire Gauge |
|
WMA 24 |
15 |
14 |
WHK 10 |
60 |
6 |
|
WMA 36 |
15 |
14 |
WHK 10 |
60 |
6 |
|
WHK 15 |
60 |
25 |
- |
6 |
10 |
- |
|
WMA 48 |
15 |
14 |
WHK 15W |
60 |
25 |
- |
6 |
10 |
- |
|
WHK 20 |
60 |
50 |
- |
6 |
8 |
- |
|
WMA 60 |
15 |
14 |
WHK 15W |
60 |
25 |
- |
6 |
10 |
- |
|
WHK 20 |
60 |
50 |
- |
6 |
8 |
- |
|
WHK 25 |
60 |
50 |
25 |
6 |
8 |
10 |
|