WUN/WND/W9M
(Single-Stage) |
|

 |
The WUN/WND/W9M Series furnaces are designed to save you money on utility bills. The
condensing gas furnace may be installed as a single pipe system, using
indoor air for combustion, or as a 2-pipe sealed combustion system,
bringing in fresh outdoor air for combustion. Since the flue gases are
at a much lower temperature, the furnace may be vented vertically or
horizontally with schedule 40 PVC or ABS pipe. Plus, the unit is Air
Conditioning ready with an adjustable speed blower motor for maximum
comfort. These furnaces are factory assembled, wired and tested to
assure safe, dependable and economical operation. Designed for both
residential and commercial installations.
When matching with an A/C System, make sure to
match the evaporator coil case width to the width of the furnace.
(The width of the furnace is shown in bold in the
specifications listed below.)
For assistance deciding what type of furnace
to select, see our page on
Heating Basics.
2-Stage High Efficiency Furnaces are also
available.
     
|
|
|
|
|
FEATURES |
|
-
Natural gas ready; LP convertible with optional kit
listed below
-
Self-diagnostic control module saves
time on servicing and troubleshooting
-
Electronic hot surface ignition
increases safety and efficiency
-
Direct Drive, permanently lubricated
blower motor has adjustable speed to maximize comfort level
-
Induced combustion system with
sealed, in-shot main burners for quiet, efficient operation
-
May be vented horizontally or vertically
with Schedule 40 PVC pipe
-
Tubular aluminized steel primary
heat exchanger, with stainless steel secondary heat exchanger
-
The W9M Series furnace delivers
95% AFUE (not all BTU sizes available, see below)
Energy Star® Compliant
Approved for use in California by the CEC
Not Certified for Mobile
Home Use
|
|
HOW TO
SELECT A 90%+ EFFICIENT GAS FURNACE |
|
Estimating the Furnace Size |
 |
|
You can refer to an estimate or
proposal from a local contractor, refer to the size of your existing
system that you may want replaced, or use the sizing estimation
chart provided on this page.
Use the map to determine your
Region based on the location of your home. Using the equipment
charts, find your Region and go down the column to locate the
range that covers the Square Footage of your home. Follow the
row to the right to determine the recommended Furnace for your
application. |
|
NOTE: These tables and charts are
intended to be used as a guideline only. The information is based on
conventional window space (<15%), insulation and building
construction. Only use these tables as a reference. When including a
finished basement, use 1/2 of the finished basement square footage
with the rest of the area being calculated. |
90%+
AFUE GAS FURNACE SELECTION GUIDE
|
SQUARE FOOTAGE OF YOUR HOME |
FURNACE SIZE |
|
REGION
1 |
REGION 2 |
REGION 3 |
REGION 4 |
REGION
5 |
|
900-1325 |
975-1450 |
1100-1600 |
1325-1950 |
1500-2200 |
60,000 BTU |
|
1325-1800 |
1450-1950 |
1600-2175 |
1950-2650 |
2200-2950 |
80,000 BTU |
|
1800-2275 |
1950-2450 |
2175-2700 |
2650-3325 |
2950-3750 |
100,000 BTU |
|
2275-2725 |
2450-2950 |
2700-3300 |
3325-4000 |
3750-4500 |
120,000 BTU |
|
|
60,000 BTU Gas
Furnace
(Choose One Furnace) |
|
UPFLOW ONLY Applications |
|
Item # |
Input/Output BTU |
Dimensions
(in.)
(h x w x d)
|
Avail.
Tons |
Outlet
(w x d) |
Wt.
(lbs.) |
|
W9M060-317 |
60,000/57,000 |
33 x 17.5 x 29.5 |
1.5-3.0 |
16.375 x 20 |
150 |
|
|
|
DOWNFLOW/HORIZONTAL Applications |
|
Item # |
Input/Output BTU |
Dimensions
(in.)
(h x w x d)
|
Avail.
Tons |
Outlet
(w x d) |
Wt.
(lbs.) |
|
WND 060-3C |
60,000/55,000 |
40 x 17.5 x 28.5 |
1.5-3.0 |
15.125 x 19.25 |
150 |
|
|
80,000 BTU Gas
Furnace
(Choose One Furnace) |
|
UPFLOW ONLY Applications |
|
Item # |
Input/Output BTU |
Dimensions
(in.)
(h x w x d)
|
Avail.
Tons |
Outlet
(w x d) |
Wt.
(lbs.) |
|
WUN 080-3C |
80,000/75,000 |
40 x 17.5 x 28.5 |
1.5-3.0 |
16.25 x 20 |
158 |
|
|
|
DOWNFLOW/HORIZONTAL Applications |
|
Item # |
Input/Output BTU |
Dimensions
(in.)
(h x w x d)
|
Avail.
Tons |
Outlet
(w x d) |
Wt.
(lbs.) |
|
WND 080-3C |
80,000/75,000 |
40 x 17.5 x 28.5 |
1.5-3.0 |
15.125 x 19.25 |
158 |
|
|
100,000 BTU Gas
Furnace
(Choose One Furnace) |
|
UPFLOW ONLY Applications |
|
Item # |
Input/Output BTU |
Dimensions
(in.)
(h x w x d)
|
Avail.
Tons |
Outlet
(w x d) |
Wt.
(lbs.) |
|
W9M100-421 |
100,000/95,000 |
33 x 21 x 29.5 |
2.5-4.0 |
19.875 x 20 |
178 |
|
|
|
DOWNFLOW/HORIZONTAL Applications |
|
Item # |
Input/Output BTU |
Dimensions
(in.)
(h x w x d)
|
Avail.
Tons |
Outlet
(w x d) |
Wt.
(lbs.) |
|
WND 100-5C |
100,000/95,000 |
40 x 21 x 28.5 |
3.5-5.0 |
18.5 x 19.25 |
178 |
|
|
120,000 BTU Gas
Furnace |
|
UPFLOW ONLY Applications |
|
Item # |
Input/Output BTU |
Dimensions
(in.)
(h x w x d)
|
Avail.
Tons |
Outlet
(w x d) |
Wt.
(lbs.) |
|
WUN 120-5C |
120,000/112,000 |
40 x 24.5 x 28.5 |
3.5-5 |
23.25 x 20 |
195 |
|
|
|
|
OPTIONAL ACCESSORIES |
|
Item # |
Description |
Wt.
(lbs.) |
|
LP 347 |
LP (Propane) Conversion Kit |
1 |
|
CB 417 |
17.5" Combustible Base - For Downflow
(Heat Only) Applications
For floors constructed of
combustible material. |
9 |
|
CB 421 |
21" Combustible Base - For Downflow
(Heat Only) Applications
For floors constructed of
combustible material. |
10 |
|
WKDP 20 |
Universal Trim-to-Fit Plenum
(Heat Only) Applications
For Furnace Openings up to 20"w x
20"d. |
28 |
|
RA 16 |
Return Air Drop - For Upflow
Applications Only |
50 |
|
|
|
Additional