96%
EFFICIENT
MULTI-POSITIONAL
Residential GAS FURNACES |
 |
The W9V Series
furnace can be installed in upflow or horizontal applications and can be
easily converted for downflow applications. The compact cabinet height of only
33" makes the unit perfect for basements, closets, attics, garages and
commercial applications. the furnace is air conditioning ready with a ECM
variable speed blower motor for maximum comfort and cooling SEER enhancement.
All units are factory assembled, wired and tested to assure safe, dependable and
economical operation. These furnaces are designed for both residential and
commercial installations and offer a more even comfort throughout while
operating at 96%AFUE.. The condensing gas furnace may be installed as a single
pipe system, using indoor air for combustion, or as a 2-pipe sealed combustion
system, bringing in fresh outdoor air for combustion. Since the flue gases
are at a much lower temperature, the furnace may be vented vertically or
horizontally with schedule 40 PVC or ABS pipe.
10-Year Limited Parts Warranty*
LIFETIME Heat Exchanger Warranty
   
*Please Note:
To qualify for the extended 10-Year Limited Parts Warranty, the unit must be
registered online at
www.upgproductregistration.com within 90 days of purchase for
replacement or closing for new home construction. Otherwise, the standard
5-Year Limited Parts Warranty is in effect. |
|
Qualifies for
up to
$200.00
per the
2011 Federal Tax Credit
Click Here for
Details |
|
 |
Installation Manual |
Replacement Parts |
Quick Reference Guide |
|
|
Technical Guide |
Warranty/User's Guide |
LP Conversion manual |
|
|
To Print your
2010
Tax Credit Certificate for Qualifying Gas Furnace
Models,
Click Here. |
|
(Please Note: Qualifying WINCHESTER
gas furnace models can be found on Page 37 of the document.
Refer to the manufacturer's model number on your equipment.) |
FEATURES
-
Two stage heating operation includes two stage gas
valve, two stage inducer operation and variable speed ECM blower
operation
-
Adjustable delay timer allows two stage operation with
a single stage thermostat
-
Natural gas ready, may be field
converted to LP Gas (Propane) with optional conversion kit (LP 347)
-
Multi-positional design with compact cabinet height of 33 inches
-
ECM variable speed drive motor for
cooling SEER enhancement, improved comfort with optional airflow delay
profiles, and continuous fan options for IAQ performance
-
Minimal
conversion for downflow application (additional clearance needed for
venting)
-
Control board with high level self-diagnostics
and fault code displays to save
time on servicing and troubleshooting
-
Electronic hot surface ignition
increases safety and efficiency
-
Induced combustion system with
in-shot main burners for quiet, efficient operation
-
Horizontal and vertical venting
w/PVC pipe
-
High tech tubular aluminized steel primary
heat exchanger, with stainless steel tube/aluminum fin secondary heat exchanger
for outstanding efficiency
Approved for use in California
Not Certified for Mobile
Home use |
|
HOW TO
SELECT A 96% EFFICIENT GAS FURNACE |
|
Estimating the Furnace Size |
 |
|
You can refer to an estimate or
proposal from a local contractor, refer to the size of your existing
system that you may want replaced, or use the sizing estimation
chart provided on this page.
Use the map to determine your
Region based on the location of your home. Using the equipment
charts, find your Region and go down the column to locate the
range that covers the Square Footage of your home. Follow the
row to the right to determine the recommended Furnace for your
application. |
|
NOTE: These tables and charts are
intended to be used as a guideline only. The information is based on
conventional window space (<15%), insulation and building
construction. Only use these tables as a reference. When including a
finished basement, use 1/2 of the finished basement square footage
with the rest of the area being calculated. |
96%
AFUE MULTI-POSITIONAL GAS FURNACES SELECTION
|
SQUARE FOOTAGE OF YOUR HOME |
FURNACE SIZE |
|
REGION
1 |
REGION 2 |
REGION 3 |
REGION 4 |
REGION
5 |
|
1130-1415 |
1220-1525 |
1365-1705 |
1660-2070 |
1855-2320 |
60,000
BTU |
|
1415-1875 |
1525-2025 |
1705-2265 |
2070-2700 |
2320-3080 |
80,000 BTU |
|
1875-2340 |
2025-2525 |
2235-2790 |
2700-3390 |
3080-3800 |
100,000 BTU |
|
2340-2775 |
2525-3025 |
2790-3350 |
3390-4070 |
3800-4560 |
120,000 BTU |
|
|
96% AFUE MULTI-POSITIONAL
GAS FURNACE MODELS |
|
Hamilton |
BTU Input |
BTU Output |
Dimensions |
Avail. |
Outlet |
Wt. |
|
Model Number |
1-Stage/2-Stage |
1-Stage/2-Stage |
H x W x D (in.) |
Tons |
Opening |
lbs. |
|
W9V060-317 |
60,000 /
39,000 |
58,000 / 37,000 |
33 x 17.5 x 29.5 |
2.0-3.0 |
16.375 x 20 |
122 |
|
W9V080-317 |
80,000 /
52,000 |
77,000 / 50,000 |
33 x 17.5 x 29.5 |
2.0-3.0 |
16.375 x 20 |
126 |
|
W9V100-421 |
100,000 /
65,000 |
96,000 / 62,000 |
33 x 21 x 29.5 |
2.5-4.0 |
19.875 x 20 |
142 |
|
W9V120-524 |
120,000 /
78,000 |
115,000 / 75,000 |
33 x 24.5 x 29.5 |
3.5-5.0 |
23.375 x 20 |
156 |
|
Optional Accessories |
|
Item # |
Description |
Wt. (lbs.) |
|
LP 347 |
LP (Propane) Conversion Kit |
1 |
|
RA 16 |
Return Air Drop - For Upflow
Applications Only |
50 |
|
WKDP 20 |
20"w x 20"d x 47'h Universal Trim to Fit Plenum
|
28 |
|
CB 414/514 |
Combustible Base for 14.5"
Downflow Applications - Heat Only* |
8 |
|
CB 417/517 |
Combustible Base for 17.5"
Downflow Applications - Heat Only* |
9 |
|
CB 421/521 |
Combustible Base for 21" Downflow
Applications - Heat Only* |
10 |
|
*PLEASE NOTE:
Combustible Base is only required for downflow, heat ONLY
applications where the surface is combustible such as a wood
sub-floor. |
|
|
|
Additional