Kelivinator® 95% Efficiency 2-Stage Fixed Speed Multi-Position Gas Furnaces

Description


For excellent comfort control and efficiency, the KG7TC Series 2-stage gas furnace can be installed in upflow or horizontal applications, and has a compact cabinet height of only 34 1/2″ making the unit perfect for basements, closets, attics, garages and commercial applications. The furnace is air conditioning ready with an ECM fixed speed blower motor for maximum comfort and efficiency. All units are factory assembled, wired and tested to assure safe, dependable and economical operation. These furnaces are designed for both residential and commercial installations and make a great choice whether installing as new or replacing an old, inefficient furnace. Not approved for mobile home installation. Not approved for installation in CA per new emissions standards.

10-Year Limited Parts Warranty*
Limited Lifetime Heat Exchanger Warranty



*Please Note: To qualify for the extended 10-Year Limited Parts Warranty, the unit must be registered online at www.nordynewarranty.com within 90 days of purchase for replacement or closing for new home construction. Otherwise, the standard 5-Year Limited Parts Warranty is in effect.

Tech Guide

User Guide

Installation Manual

Features


FEATURES

Two stage heating operation includes two stage gas valve, two stage inducer operation and fixed speed ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat

Natural gas ready, may be field converted to LP Gas (Propane) with optional conversion kit (GLP028)

Designed for upflow and horizontal applications with a compact cabinet height of 34 1/2 inches

Control board with high level self-diagnostics and fault code displays to save time on servicing and troubleshooting

Electronic hot surface ignition increases safety and efficiency

ECM fixed speed drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance

In-shot burners and sealed combustion for safe, quiet, and efficient operation

Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air with schedule 40 PVC/ABS pipe

High tech tubular aluminized steel primary and stainless steel secondary heat exchangers

Not Certified for Mobile Home use

Certified for use in California

Sizing Guide


HOW TO SELECT A 95% EFFICIENT 2-STAGE FIXED SPEED ECM GAS FURNACE
You can refer to an estimate or proposal from a local contractor, refer to the size of your existing system that you may want replaced, or use the sizing estimation chart provided on this page. Use the map to determine your Region based on the location of your home. Using the equipment charts, find your Region and go down the column to locate the range that covers the Square Footage of your home. Follow the row to the right to determine the recommended Furnace for your application.

HowToSelect80EfficientFurnaceMap2

 

Square Footage of Your Home Furnace Model #
925-1390 1000-1500 1110-1675 1350-2035 1520-2280 KG7TC060D-24B
1390-1850 1500-2000 1675-2235 2035-2700 2280-3040 KG7TC080D-35C
1850-2310 2000-2500 2235-2790 2700-3390 3040-3800 KG7TC100D-35C
2310-2775 2500-3000 2790-3350 3390-4070 3800-4560 KG7TC120D-45D

 

NOTE: These tables an charts are intended to be used as a guideline only. The information is based on conventional window space (<15%), insulation and builing construction. Only use these tables as a reference. When including a finished basement, use 1/2 of the finished basement square footage with the rest of the area being calculated.

Models & Specs


95% AFUE 2-Stage Variable Speed Multi-Positional Gas Furnace Models

Kelvinator Model Number 1st Stage BTU Input/Output 2nd Stage BTU Input/Output Dimensions H x W x D (in.) Available Tons Supply Outlet W x D (in.) Ship Wt (lbs.) Energy Guide
KG7TC060D-24B 39,000 / 37,050 60,000 / 57,000 34.5 x 17.5 x 28 2.0 – 4.0 15.875 x 19 125 EnergyGuideIcon2
KG7TC080D-35C 52,000 / 49,400 80,000 / 76,000 34.5 x 21 x 28 3.0 – 5.0 19.375 x 19 135 EnergyGuideIcon2
KG7TC100D-35C 65,000 / 61,750 100,000 / 95,000 34.5 x 21 x 28 3.0 – 5.0 19.375 x 19 145 EnergyGuideIcon2
KG7TC120D-45D 78,000 / 74,100 120,000 / 114,000 34.5 x 24.5 x 28 4.0 – 5.0 22.875 x 19 160 EnergyGuideIcon2

*Please Note: 5 Ton/2000 CFM applications require two (2) side air returns.

Optional Furnace Accessories

Item No. Description Weight (lbs.)
GLP-028 LP (Propane) Conversion Kit for all KG7TC Series Furnaces 1
RA 16 Return Air Drop Assembly (Upflow Applications Only) 50
WKDP 20 Universal Trim to Fit Plenum – 20″ x 20″ x 47″ (for Heat Only Applications) 28

*Please Note: Combustible Base is only required for downflow, heat only applications where the surface is combustible (ex. wood sub-floor).

Find in Stores