Kelvinator® 14 SEER R-410A Heat Pumps Systems

Description


Stay comfortable with this single phase 14 SEER sweat heat pump system designed for residential applications and consists of the outdoor heat pump condenser, air handler with evaporator coil, electric heat kit, and 30 ft. line set. The condenser is charged with R-410A refrigerant and has a top air discharge. The one-piece air handler houses the dry nitrogen charged evaporator coil, and is designed for upflow, downflow, and horizontal applications. The Line Set is 30 ft. in length and includes the liquid line and insulated suction line. The system is AHRI Listed and Certified, ETL Listed. Final connections from line set to coil and condenser must be done by a certified technician.

PLEASE NOTE: Due to the NEW 2015 Federal Regional Standards for Heating and Cooling Products, customers located in the Southeastern Region consisting of the following states are required to have systems installed that are a minimum of 14 SEER:AL, AK, DE, FL, GA, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA. Customers located in the Southwestern Region consisting of the following states are required to have systems installed that are a minimum of 14 SEER, 12.2 EER ≤ 3.5 tons, 11.7 EER ≥ 4 tons: AZ, CA, NV, NM.

10-Year Limited Parts and Compressor Warranty*

WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov

*Please Note: To qualify for the extended 10-Year Limited Parts Warranty, the unit must be registered online at www.nordynewarranty.com within 90 days of purchase for replacement or closing for new home construction. Otherwise, the standard 5-Year Limited Parts Warranty is in effect.

Condenser Tech Guide

User Guide

Condenser Installation Manual

Air Handler Installation Manual

Features


Sweat fit system includes outdoor heat pump condenser, one-piece air handler with evaporator coil, thermal expansion valve, and 30 ft. line set

Outdoor condenser is pre-charged with enough R-410A refrigerant for a 15 ft. line set; additional charge must be added in the field for longer line set applications

One piece air handler with evaporator coil is designed for upflow, downflow, and horizontal installation applications

The heat kit is easy to install with simply plug-in connections – must be field installed

30 ft. line set includes liquid line and insulated suction line

Internally protected scroll compressor to guard against high pressure and temperature

Not for Mobile Home Use

Sizing Guide

HOW TO SELECT A 14 SEER SWEAT-FIT HEAT PUMP SYSTEM

You can refer to an estimate or proposal from a local contractor, refer to the size of your existing system that you may want replaced, or use the sizing estimation chart provided on this page. Use the map to determine your Region based on the location of your home. Using the equipment charts, find your Region and go down the column to locate the range that covers the Square Footage of your home. Follow the row to the right to determine the recommended Furnace for your application.

HowToSelect80EfficientFurnaceMap2

Square Footage of Your Home Heat Pump System Size
935-1310 800-1235 830-1165 680-955 680-955 1.5 Ton
1310-1680 1235-1580 1165-1500 955-1225 955-1225 2.0 Ton
1680-2060 1580-1940 1500-1830 1225-1500 1225-1500 2.5 Ton
2060-2435 1940-2290 1830-2165 1500-1770 1500-1770 3.0 Ton
2435-2810 2290-2645 2165-2500 1700-2045 1700-2045 3.5 Ton
2810-3375 2645-3175 2500-3000 2045-2455 2045-2455 4.0 Ton
3375-3935 3175-3705 3000-3500 2455-2860 2455-2860 5.0 Ton

 

NOTE: These tables an charts are intended to be used as a guideline only. The information is based on conventional window space (<15%), insulation and builing construction. Only use these tables as a reference. When including a finished basement, use 1/2 of the finished basement square footage with the rest of the area being calculated.

Models & Specs


14 SEER R-410A Heat Pump Systems

System Model Number Ton Size Comp. Type Condenser H x W x D (in.) Max Amps Air Handler H x W x D (in.) Heat Kit (kW) System Ship Wt. (lbs.) Energy Guide
JT4BE-018KA 1.5 Scroll 31.5 x 30.75 x 30.75 20 43.3125 x 14.1875 x 22 8 – 10 298 EnergyGuideIcon2
JT4BE-024KA 2.0 Scroll 31.5 x 30.75 x 30.75 30 43.3125 x 14.1875 x 22 8 – 10 303 EnergyGuideIcon2
JT4BE-030KA 2.5 Scroll 39.5 x 30.75 x 30.75 25 43.3125 x 19.6875 x 22 10 – 15 315 EnergyGuideIcon2
JT4BE-036KA 3.0 Scroll 43.5 x 30.75 x 30.75 30 49.3125 x 19.6875 x 22 15 – 20 368 EnergyGuideIcon2
JT4BE-042KA 3.5 Scroll 43.5 x 30.75 x 30.75 40 49.3125 x 19.6875 x 22 15 – 20 393 EnergyGuideIcon2
JT4BE-048KA 4.0 Scroll 43.5 x 30.75 x 30.75 45 55.9375 x 22.4375 x 22 20 417 EnergyGuideIcon2
JT4BE-060KA 5.0 Scroll 43.5 x 30.75 x 30.75 60 55.9375 x 22.4375 x 22 20 435 EnergyGuideIcon2

Optional Heat Pump Accessories

Item Number Description Weight (lbs.)
WKDP 20 Trim-to-fit Plenum for Cased Coil Applications up to 47″ H x 20″ W x 20″ D 28
WKDP 24 Trim-to-fit-Plenum for Cased Coil Applications up to 47″ H x 24.5″ W x 20″ D 35
1F72-151 5/2 Day Heat Pump Programmable Thermostat (Single Stage) 1
Find in Stores